Analisis Getaran Primary Air Fan (PAF) Sebagai Dasar Maintenance Pada Sistem Boiler CFB MB 26 PT Indah Kiat Pulp and Paper Tbk Perawang
DOI:
https://doi.org/10.37338/6qg8d659Keywords:
Primary Air Fan, Analisis getaran , Predictive maintenance, ISO 10816-3, Boiler CFBAbstract
Primary Air Fan (PAF) is an important rotating equipment in the Circulating Fluidized Bed (CFB) boiler system that supplies primary air to support the fluidization and combustion processes. The reliability of the PAF significantly affects combustion stability and steam production continuity. This study aims to analyze the vibration characteristics of Primary Air Fan units as a basis for predictive maintenance implementation in the Boiler CFB MB 26 system at PT Indah Kiat Pulp and Paper Tbk Perawang. Vibration measurements were conducted using an SKF QuickCollect Sensor, while bearing temperatures were measured using an infrared thermal gun. The collected data were analyzed using the Root Mean Square (RMS) method and evaluated according to ISO 10816-3 standards. The results showed that PAF A had a maximum vibration value of 0.5 mm/s and was classified in Zone A (Good Condition), while PAF B reached 1.7 mm/s and was classified in Zone B (Acceptable Condition) with an indication of slight unbalance. Bearing temperatures ranged from 31.1°C to 42.4°C and remained within normal operating limits. The results indicate that vibration analysis is effective for machine condition monitoring and supports predictive maintenance implementation
References
M. Romanssini, P. C. C. de Aguirre, L. Compassi-Severo, and A. G. Girardi, "A Review on Vibration Monitoring Techniques for Predictive Maintenance of Rotating Machinery," Eng, vol. 4, no. 3, pp. 1797–1817, 2023.
M. Tiboni, C. Remino, R. Bussola, and C. Amici, "A Review on Vibration-Based Condition Monitoring of Rotating Machinery," Applied Sciences, vol. 12, no. 3, p. 972, 2022.I. N. Darmawan, Kholistianingsih, A. Purwanto, and P. Yulianto, "Pengurangan Gangguan Akibat Kegagalan Pengukuran Vibrasi pada Primary Air Fan (PAF) di PLTU Jateng 2 Adipala Operation and Maintenance Services Unit," J-Proteksion, vol. 7, no. 2, pp. 35–46, 2023.
S. Kumar and S. Kumar, "Vibration Response-Based Condition Monitoring and Fault Diagnosis of Rotary Machinery," Materials Today: Proceedings, vol. 50, pp. 679–683, 2022.
S. Aburakhia, T. Tayeh, R. Myers, and A. Shami, "Similarity-Based Predictive Maintenance Framework for Rotating Machinery," 2022.
S. Kiranyaz, O. C. Devecioglu, A. Alhams, S. Sassi, T. Ince, O. Avci, and M. Gabbouj, "Exploring Sound vs Vibration for Robust Fault Detection on Rotating Machinery," 2023.
ISO 10816-3, Mechanical Vibration—Evaluation of Machine Vibration by Measurements on Non-Rotating Parts—Part 3: Industrial Machines with Nominal Power Above 15 kW, International Organization for Standardization, Geneva, Switzerland, 2009.
A. Rai and S. Upadhyay, "A Review on Condition Monitoring and Predictive Maintenance of Rotating Machinery," Measurement, vol. 220, 2024. Machinery," 2023.
M. Cerrada, R. Sánchez, C. Li, and D. Cabrera, "Machine Condition Monitoring and Fault Diagnosis Using Vibration Analysis: A Review," Mechanical Systems and Signal Processing, vol. 188, 2023.
Y. Wang, H. Li, and X. Zhang, "Predictive Maintenance for Industrial Rotating Equipment Based on Vibration Monitoring," Sensors, vol. 24, no. 2, 2024.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Armin Jon Tua Manalu, Abdul Gafur

This work is licensed under a Creative Commons Attribution 4.0 International License.